What should I do if the floor heating pipe leaks? Comprehensive analysis of causes, detection and maintenance plans
Recently, leaking floor heating pipes have become a hot topic in home maintenance in winter, especially when the cold wave hits, such problems occur frequently. The following is a structured analysis and solution for this problem, compiled based on hot data from the entire network in the past 10 days.
1. Analysis of common causes of floor heating water leakage

| Reason type | Proportion | Typical cases |
|---|---|---|
| Pipe aging and cracking | 35% | PE-RT pipes used for more than 10 years |
| Improper construction | 28% | The interface is not welded firmly |
| external force damage | 20% | Pipes accidentally damaged by decoration drilling |
| water corrosion | 12% | Failure to install a filter causes corrosion |
| Others | 5% | Animal bites etc. |
2. Comparison of water leakage detection methods
| Detection method | Accuracy | Cost | Applicable scenarios |
|---|---|---|---|
| Infrared thermal imager | 90% | high | Concealed Engineering |
| stress testing method | 85% | in | Unfurnished house |
| audiometer | 75% | low | tile floor |
| observation method | 60% | zero | Obvious water seepage area |
3. Emergency steps
1.Close the valve immediately: Locate the main valve (usually the red handle) on the water distributor and turn it clockwise until it is completely closed.
2.cut off power: Turn off the floor heating thermostat to avoid idling damage to the water pump.
3.Drainage treatment: Use a towel to absorb open water. In serious cases, contact the property management company to close the valves on the entire floor.
4.Mark missing points: Use waterproof tape to circle the water seepage area to facilitate repair and location.
4. Maintenance plan selection guide
| Damage | Maintenance method | Fee reference | Construction period |
|---|---|---|---|
| Single point damage (≤2cm) | Special clamp repair | 200-500 yuan | 2 hours |
| The interface is loose | Hot melt re-welding | 300-800 yuan | half a day |
| Extensive corrosion | partial pipe replacement | 1500-3000 yuan | 1-2 days |
| Aging pipes throughout the house | System reinstallation | 8000 yuan+/㎡ | 3-7 days |
5. Suggestions on preventive measures
1.annual stress test: Conduct a 0.8MPa pressure holding test before the heating season, and the pressure drop ≤0.05MPa in 30 minutes is considered qualified.
2.Install leak alarms: The new smart sensor can push water leakage alarms on mobile phones, with an average price of about 200 yuan/set.
3.Avoid extreme heating: When first used, the temperature rise should not exceed 5°C per day to prevent thermal expansion and cold contraction from exploding the pipe.
4.Choose corrosion-resistant pipes
According to the Baidu Index, the search volume for the keyword "floor heating leaking" has increased by 173% year-on-year in the past 10 days. It is recommended that users collect this emergency guide and check the pipeline system regularly.